Technical Information - Material Properties

 
   
       
Material Densities:
 

Non-structural applications range from 300 - 700kg p/cm density
Structural applications range from 800 - 1600kg p/cm density

Compressive Strength:
 
Structural range 9 - 25 Nmm2 - Mp
Tensile Strength:
 
3 - 9 Nmm2 - Mp
Modulus of Elasticity:
 
1,200 - 10,000 Nmm2 - Mp
Shrinkage in 28 Days:
 
0.2%
Water proof:
  From 80mm thickness
Fire Resistance:
 

For non-load bearing walls 1 hour for every 50mm thickness
For load bearing walls & floors 1 hour every 100mm thickness

Thermal Conductivity:
  W/mk is the metric value of the thermal conductivity, which is given by
the letter "K", thermal resistance "R" is derived: R = t/k, where
R is the thermal resistance and t is thickness in (mm)
Example: for 100 mm of thickness of material, t = 100. Therefore the
lowest density, where K = 0.079, we have: R 100 : 0.079 = 1.26


   
 
 Density W/m.K 50 80 100 125 150 200 250 300 350
  300 D. 0.079 0.63 1.01 1.26 1.58 1.89 2.53 3.16 3.79 4.42
  400 D. 0.102 0.49 0.79 0.98 1.22 1.47 1.96 2.45 2.94 3.43
  500 D. 0.116 0.43 0.69 0.86 1.07 1.29 1.72 2.15 2.58 3.01
  600 D. 0.148 0.33 0.54 0.67 0.84 1.01 1.35 1.69 2.02 2.35
  700 D. 0.160 0.31 0.50 0.62 0.78 0.93 1.25 1.56 1.87 2.18
  800 D. 0.180 0.27 0.44 0.55 0.69 0.83 1.11 1.39 1.66 1.93
  900 D. 0.208 0.24 0.38 0.48 0.60 0.72 0.96 1.20 1.44 1.68
  1000 D. 0.244 0.20 0.32 0.41 0.51 0.61 0.82 1.02 1.23 1.43

 

 

 
       
       
 
Phone + 61 7 3343 3844 | Fax + 61 7 3343 3818 | E-Mail info@LitecreteIndustries.com
PO box 532 Mt Gravatt, Brisbane Australia, 4122